Firmware 03.00 - DMS EN 5.0 - 07/2009 L 49
8400 BaseLine D | Software Manual
Drive control (DCTRL)
Device states
4.1.4 "ReadyToSwitchON" state
This is the device state of the controller after the initialisation is completed!
The bus systems are running and the terminals and encoders are evaluated.
The monitoring modes are active.
The controller can be parameterised.
The application is executable.
Auto-start option C00142 = 1
: Auto restart inhibited after power-up
When the auto-start option C00142 = 1
(inhibit when "Mains on", Lenze setting) has
been selected, the controller inhibit must always be cancelled after power-up so that
the controller can change from the "Device is ready to switch on" to the "Device is
switched on":
[4-3] State change when auto restart is inhibited (C00142 = "1")
LED DRIVE READY LED DRIVE ERROR Display in C00137
OFF ReadyToSwitchON
Controller pulses are inhibited
Controller pulses are enabled
n
o
With controller inhibit at power-up
Without controller inhibit at power-up
RFR
01
RFR
RFR
RFR
t
t
Initialisation Switched on OperationReady to switch on
Initialisation Switched on OperationReady to switch on

Table of Contents