Ethernet Message Sending
The device can be used for sending a message to a certain IP:port address. The three different commands
allow controlling the connected (third-party) devices. #message
Sending a TCP Message (ASCII-format)
The command is for sending a command message in ASCII-format. This method allows escaping the control
characters. For more information see the Escaping section.
Command and Response
ç <IP_address>:<port_no><message>)
æ 
Example
ç 
æ 
The 'C00' message is sent to the indicated IP:port address.

ç 
æ 

Using Hexadecimal Codes section.
Sending a TCP Text (ASCII-format)
The command is for sending a text message in ASCII-format. This method does not allow escaping or inserting
control characters.
Command and Response
ç <IP_address>:<port_no><text>)
æ 
Example
ç 
æ 
The 'pwr_on' text is sent to the indicated IP:port address.

The command is for sending a binary message in Hexadecimal format. This method does not require escaping
or inserting control characters.
Command and Response
ç <IP_address>:<port_no><HEX_message>)
æ 
Example
ç 
æ 
The '0100000061620000cdcc2c40' message is sent to the indicated IP:port address.
INFO: There is no need to insert a space or other separator character between the binary messages.
Sending UDP Message (ASCII-format)
The command is for sending a UDP message in ASCII-format. This method allows escaping the control characters.
For more information see the Escaping section.
Command and Response
ç <IP_address>:<port_no><message>)
æ 
Example
ç 
æ 
The 'C00' message is sent to the indicated IP:port address.

ç 
æ 

sequence indicates the HEXA code; see more information in the Using Hexadecimal Codes section.

Table of Contents

Other manuals for Lightware MMX8x4-HT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware MMX8x4-HT Series and is the answer not in the manual?

Lightware MMX8x4-HT Series Specifications

General IconGeneral
BrandLightware
ModelMMX8x4-HT Series
CategoryMatrix Switcher
LanguageEnglish

Related product manuals