EasyManuals Logo
Home>Mindray>Diagnostic Equipment>ME8

Mindray ME8 Operator's Manual

Mindray ME8
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #261 background imageLoading...
Page #261 background image
18 System Maintenance
Operator’s Manual 18 - 5
If you spill liquid on the main unit, disconnect the power supply, dry the
main unit, and contact your service personnel.
Never use abrasive materials (such as steel wool or silver polish), or
erosive cleaners (such as acetone or acetone-based cleaners).
Dilute and use the disinfectants according to the manufacturer's
instructions.
Check the system after disinfection. If there is any sign of damage, remove
it from use.
Follow local regulations when selecting and using the disinfectant.
Disinfectants listed in this section are used for disinfecting the housing of
the main unit and the monitor only, not for disinfecting the probes or the
trolley.
During cleaning, wear medical gloves to prevent infection.
Compatible Disinfectants
The following table lists compatible disinfectants.
Disinfection Procedures
NOTE:
The system has passed puncture test and leakage current test, and thus can be disinfected on power-
on status: tap > bar in the left side of the touch screen to enter the Exam Main Menu screen and then
select to lock the system for 10 seconds to disinfect the system while the power is “On”.
After cleaning, disinfect the system as follows.
1. Wear medical gloves to prevent infection.
2. Disinfect the main unit with disinfectant wipe or solution.
Follow the disinfectant manufacturers recommended contact time and method.
Only the areas highlighted in gray color as shown in the following figure can be disinfected.
Do not disinfect the top cover, bottom cover, side panels around the main unit, manufacturer
logo, any visible sockets or interfaces (such as probe socket, ventilation holes, dust-proof
cover, loudspeaker, sockets or interfaces in the IO panel and power supply panel).
Product Name Manufacturer Type
75% alcohol / Solution
99.5% isopropyl alcohol / Solution
SONO
TM
ULTRASOUND
WIPES
Advanced Ultrasound
Solutions Inc.
Wipe
Schulke mikrozid
®
Sensitive
Wipes
Schulke Wipe
Mikrobac Tissues Bode Chemie Gmbh Wipe
Sani-Cloth
®
Plus PDI Wipe

Table of Contents

Other manuals for Mindray ME8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray ME8 and is the answer not in the manual?

Mindray ME8 Specifications

General IconGeneral
BrandMindray
ModelME8
CategoryDiagnostic Equipment
LanguageEnglish

Related product manuals