EasyManuals Logo

Mitsubishi Electric CR760-D User Manual

Mitsubishi Electric CR760-D
730 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #570 background imageLoading...
Page #570 background image
6-550 Parameter for behavior selection at the error occurrence on dual system
5Functions set with parameters
5.27 Parameter for behavior selection at the error occurrence on dual system
When the parameter CATEGORY is set for the error on dual system shown in Table 5-49, the behavior of
the [RESET] key input at the error occurrence on dual system can be selected.
Table 5-49:Target error list
The behavior of the [RESET] key input is set as shown in Table 5-50.
Table 5-50:Action to the settings
To reflect the settings of this parameter, you must turn the controller's power on again.
[Note]
The setting shown in this section is to select the behavior in a state without any abnormalities on the related
signal lines or wiring.
With the abnormalities, the errors shown above cannot be reset regardless of the parameter setting.
Error number Content
H0039 Door Switch Signal line is faulty.
H0046 Faulty wiring (Enabling Device).
H0051 Wiring of the external emergency stop is abnormal.
Parameter settings Content
3 (Enable the error reset) Error can be reset. (Default settings)
4 (Disable the error reset) Error cannot be reset.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric CR760-D and is the answer not in the manual?

Mitsubishi Electric CR760-D Specifications

General IconGeneral
BrandMitsubishi Electric
ModelCR760-D
CategoryController
LanguageEnglish

Related product manuals