EasyManuals Logo
Home>MTS Systems>Controller>FlexTest IIm

MTS Systems FlexTest IIm User Manual

Default Icon
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #182 background imageLoading...
Page #182 background image
MTS 793 Controller Hardware FlexTest IIm Controller Connections
181
Digital Outputs • Digital outputs provide an optically isolated open collector/open
emitter output.
• The digital outputs are controlled by the Digital Output process in
the MultiPurpose TestWare application. They can also be
controlled manually in the Station Manager application.
• Each digital output connector located on the Digital I/O Access
Panel supports two channels.
• Each digital output is an open collector/open emitter rated at 30 V
DC max at 50 mA max.
J1 - 2
6
2
1
7
X1
12 volt common
+CH1
-CH1
External Switch
or
Relay Contact
External Device
3
21
+12 VDC
+12 VDC
J3 - 4
9
4
5
8
X4
12 volt common
+CH4
-CH4
External Device
3
21
+12 VDC
+12 VDC
Digital I/O
Access Panel
498 Digital I/O
Transition Module
Opto-
Coupler
Digital I/O
Access Panel
498 Digital I/O
Transition Module
Opto-
Coupler
This shows how to
connect an external
switch or a set of relay
contacts to channel 1 of
the digital inputs.
This shows how to
connect an external logic
signal to channel 4 of the
digital inputs.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems FlexTest IIm and is the answer not in the manual?

MTS Systems FlexTest IIm Specifications

General IconGeneral
BrandMTS Systems
ModelFlexTest IIm
CategoryController
LanguageEnglish

Related product manuals