EasyManuals Logo

Nordson ProBlue Flex Manual

Nordson ProBlue Flex
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
Tools
Maintenance
Force Fill
OLED User Interface
110
Part 1128351_02
E 2020 Nordson Corporation
Forcing the Fill System to Activate Automatic Fill
System
The Fill system is standard with Melt-on-Demand versions of the ProBlue
Flex melter and optional for tank versions.
The Fill system automatically activates if needed and when the tank is at its
set point temperature.
However, you can manually initiate the fill system using the following
methods:
- Continuous Force Fill: press the
on the Navigation pad to toggle the Fill
system On for as long as you want. Toggle it again to deactivate the Fill
system.
- Timed Force Fill:
1. Enter the Force Fill Time, or the amount of time you want the Fill system
to activate. The default is 5 seconds, minimum is 3 seconds, and the
maximum is 20 seconds.
2. Select the Activate Timed Force Fill menu option to activate the Fill
system for the amount of time you define.
Notes:
S The Master Fill control must be Enabled.
S Using either Continuous Force Fill or Timed Force Fill overrides the
overfill protection and could allow adhesive to enter the exhaust section
of the melter.
S The Fill Activity LED illuminates when the Fill system is actively
filling.

Table of Contents

Other manuals for Nordson ProBlue Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson ProBlue Flex and is the answer not in the manual?

Nordson ProBlue Flex Specifications

General IconGeneral
BrandNordson
ModelProBlue Flex
CategoryMelting Machines
LanguageEnglish

Related product manuals