Pressure
Runup
Pressure Settings
Pressure Mode
OLED User Interface
36
Part 1128351_02
E 2020 Nordson Corporation
Defining Pressure Runup Settings and Monitoring Alert
Settings
Use Pressure Runup to allow the system pressure to automatically adjust to
maintain the same adhesive output when the line speed changes. You can
optionally decide if you want to receive pressure alerts when the system
pressure, hydraulic or pneumatic exceeds the defined thresholds.
NOTES:
S The melter will go into an Alert condition only if the pressure meets or
exceeds the high/low thresholds for more than 10 seconds.
S You can change the pressure scaling from the System Settings |
Preferences. The default is pneumatic.
S The Set Point is a read-only, calculated value.
S Press on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.
Pressure Runup Output Settings
Enter the maximum/minimum pressure and line speed you want the system
to use for production.
1. Select Output Setting, press > and enter the following information:
S Low Speed Pressure Setting:
Pressure Default Minimum Maximum
PSI 20 0 90
BAR 1.38 0 6.21
kPa 138 0 621
S Low Line Speed
Pressure Default Minimum Maximum
Meter/
Minute
6.1 0 298.7
Feet/
Minute
20 0 980