Defining Adhesive Flow Monitoring Alarms
Use the Teach mode to automatically calculate the Target Add-On and
Products to Average values.
NOTE:
S Make sure the Adhesive Flow Monitoring option is enabled. (Home |
System Settings | Flow Settings)
1. Go to Home | System Settings | Flow Settings and select Monitor
Alarm Settings and select or enter the following information.
Setting Description Default Min Max
Alert Alarm Enables or disables the system from
monitoring and generating flow Alert
alarms
Note: When an Alert alarm is
generated, production continues, but
attention may be needed.
Disabled N/A N/A
Low Alert Threshold How much lower the add-on weight
(mg) can be from the Target Add-On
value before an Alert alarm is
generated.
.2 * Target
add on
value
.05 *
Target
add on
value
.5 * Target
add on
value
High Alert Threshold How much higher the add-on weight
(mg) can be from the Target Add-On
value before an Alert alarm is
generated.
.3 * Target
add on
value
.05 *
Target
add on
value
.5 * Target
add on
value
Alert Delay Count The number of consecutive
out-of-tolerance products allowed
before the system considers them
defective and generates an Alert
alarm.
4 1 15
Stop Alarm Enables or disables the system from
monitoring and generating flow Stop
alarms.
Note: When a Stop alarm is
generated, production is halted.
Immediate attention is required.
Disabled N/A N/A