6 - 23
6 Parameters
E5@C-T Digital Temperature Controllers User’s Manual (H185)
6-4 Program Setting Level
6
on1
Time Signal 1 ON Time
Outputs must be assigned to time signals 1 and 2.
on2
Time Signal 2 ON Time
• These parameters set the ON times for the time signals.
* The unit is set in the Program Time Unit parameter. (The default is H-M (hours and min-
utes).)
z Related Sections
5-15 Program-related Functions (page 5-53)
z Related Parameters
Time Signal 1 and 2 Set Segment (Program Setting Level): Page 6-22
Program Time Unit (Initial Setting Level): Page 6-58
of1
Time Signal 1 OFF Time
Outputs must be assigned to time signals 1 and 2.
of2
Time Signal 2 OFF Time
• These parameters set the OFF times for the time signals
* The unit is set in the Program Time Unit parameter. (The default is H-M (hours and min-
utes).)
z Related Sections
5-15 Program-related Functions (page 5-53)
z Related Parameters
Time Signal 1 and 2 Set Segment (Program Setting Level): Page 6-22
Program Time Unit (Initial Setting Level): Page 6-58
Function
Setting
Setting range Unit Default
0.00 to 99.59 Hours and minutes, or minutes and seconds * 0.00
See
See
Function
Setting
Setting range Unit Default
0.00 to 99.59 Hours and minutes, or minutes and seconds * 0.00
See
See