E5@C-T Digital Temperature Controllers User’s Manual (H185)
6-11 Communications Setting Level
6
6-11 Communications Setting Level
psel
Protocol Setting
u-no
Communications Unit No.
bps
Communications Baud Rate
len
Communications Data Length CompoWay/F must be selected as the protocol.
sbit
Communications Stop Bits CompoWay/F must be selected as the protocol.
prty
Communications Parity
CompoWay/F or Modbus must be selected as the
protocol.
sdwt
Send Data Wait Time
maxu
Highest Communications Unit No.
FINS or MCP4 must be selected as the protocol, or
CompoWay/F must be selected as the protocol and
the communications unit number must be set to 0.
area
Area FINS or MCP4 must be selected as the protocol.
adrh
First Address Upper Word FINS or MCP4 must be selected as the protocol.
adrl
First Address Lower Word FINS or MCP4 must be selected as the protocol.
rwat
Receive Data Wait Time FINS or MCP4 must be selected as the protocol.
unit
Communications Node Number
FINS or MCP4 must be selected as the protocol, or
CompoWay/F must be selected as the protocol and
the communications unit number must be set to 0.
up*
Upload Setting * (* = 1 to 23) FINS or MCP4 must be selected as the protocol.
dn*
Download Setting * (* = 1 to 43) FINS or MCP4 must be selected as the protocol.
copy
Copy
CompoWay/F, FINS, or MCP4 must be selected as
the protocol and the communications unit number
must be set to 0.