EasyManuals Logo
Home>Omron>Controller>NX-SID Series

Omron NX-SID Series User Manual

Omron NX-SID Series
626 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #344 background imageLoading...
Page #344 background image
The letter F in dark red is displayed
Additional Information
The number of variables you can force-refresh simultaneously is listed below.
NX-SL3300/NX-SL3500: Up to 19 variables
NX-SL5500/NX-SL5700: Up to 256 variables
l
Procedure to Cancel All Forced Refreshing from the FBD Editor
Use the following procedure to batch-clear forced refreshing.
Select Unforce Values from the Controller Menu.
All forced refreshing is cleared at once.
The letter [F] in dark red of all forced refreshing values are removed. The value will not change.
l
Procedure to Cancel Individual Forced Refreshing from the FBD Editor
Use the following procedure to individually clear forced refreshing.
1 Click the present value of the variable to change.
The following Prepare Value Dialog Box is displayed.
7 Checking Operation and Actual Operation
7 - 38
NX-series Safety Control Unit User's Manual (Z930)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX-SID Series and is the answer not in the manual?

Omron NX-SID Series Specifications

General IconGeneral
BrandOmron
ModelNX-SID Series
CategoryController
LanguageEnglish

Related product manuals