EasyManuals Logo
Home>Pioneer>Monitor>PDP-433CMX

Pioneer PDP-433CMX User Manual

Pioneer PDP-433CMX
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
137
Menu Mode
2) Setting POWER MANAGEMENT and AUTO POWER ON/OFF
To save electricity, this function automatically shifts the device into power-saving mode when no picture (sync)
signal is detected.
If not using this power-saving function
select OFF.
To enter power standby if no input signal is detected after 8 min
select AUTO POWER OFF: ON.
To switch between routine operating status and power-saving status, in accordance with the presence of signals
Select POWER MANAGEMENT: ON.
Set-able condition : POWER MANAGEMENT: INPUT 1 (personal computer signal), INPUT5
(applies only
when equipped with PDA-5002)
AUTO POWER OFF; other than the above
Factory preset : OFF
1 Select SET UP.
Screen 1
2 Move the cursor to POWER MANAGEMENT
(AUTO POWER OFF) and use the SET button to
change the setting.
Setting will change between OFF and ON each
time the SET button is pressed.
Screen 2
SELECT CHANGE EXIT
SET
MENU
PICTURE SCREEN SET UP OPTION
:
A
UTO
SETT I N
CLAMP
POWER
:
G
O
FF
PSITIONO
MNAGEMEA
INPUT INPUT
1
LEBLA
:
V
GA
:
N
T
MAIN MENU INPUT1
SELECT ENTER EXIT
SET
MENU
PICTURE SCREEN SET UP OPTION
:
V
GA
:
N
T
:
A
UTO
SETT I N
CLAMP
POWER
:
G
O
FF
PSITIONO
MNAGEMEA
INPUT INPUT
1
LEBLA
MAIN MENU INPUT1
(NOTE)
To restore routine operating status from power standby status, press the POWER button on the remote control or
main unití-s operation panel.
To restore routine operating status from power-saving status, either use a personal computer or press the INPUT
button on the remote control or main units operation panel.
However, when there is G ON SYNC or composite SYNC input, it will not be possible to restore routine operating
status via personal computer alone. The INPUT button will need to be pressed after the personal computer has
been operated appropriately.
Power consumption in power standby mode will be 1W.
Power consumption in power-saving mode will be around 1W for INPUT 1 and around 50W for INPUT 5.

Table of Contents

Other manuals for Pioneer PDP-433CMX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pioneer PDP-433CMX and is the answer not in the manual?

Pioneer PDP-433CMX Specifications

General IconGeneral
BrandPioneer
ModelPDP-433CMX
CategoryMonitor
LanguageEnglish

Related product manuals