Timing
M30240 Group
Rev.1.00 Sep 24, 2003 Page 129 of 360
Table 1.50: External interrupt INTi inputs
Table 1.47: Timer A input (up/down input in event counter mode)
Symbol Parameter
Standard
Unit
Min Max
tc(UP)TAiOUT input cycle time 2000 ns
tw(
UPH)TAiOUT input HIGH pulse width 1000 ns
tw(UPL)TAiOUT input LOW pulse width 1000 ns
tsu(
UP-TIN)TAiOUT input setup time 400 ns
th(
TIN-UP)TAiOUT input hold time 400 ns
Table 1.48: A-D trigger input
Symbol Parameter
Standard
Unit
Min Max
tc(AD)
AD
TRG
input cycle time (triggerable minimum)
1000 ns
tw(ADL)
AD
TRG
input LOW pulse width
125 ns
Table 1.49: Serial I/O
Symbol Parameter
Standard
Unit
Min Max
tc(
CK) CLKi input cycle time 200 ns
tw(
CKH) CLKi input HIGH pulse width 100 ns
tw(
CKL) CLKi input LOW pulse width 100 ns
td(
C-Q) TxDi output delay time 80 ns
th(C-Q) TxDi hold time 0 ns
tsu(
D-C) RxDi input setup time 30 ns
th(
C-D) RxDi input hold time 90 ns
Symbol Parameter
Standard
Unit
Min Max
tw(INH) INTi input HIGH pulse width 250 ns
tw(
INL) INTi input LOW pulse width 250 ns