Technical Bulletin PAGE: 2/2
Model: Model CH-C1 (Office/Pro)
SOLUTION
Do the following.
CH-C1 Pro:
Execute “Adjust Image Density” (0201-01) inside the Skilled Operator Settings.
Note: This is effective when the development gamma is low (about 0.8 or less) or the OPC electric
potential is high, such as in low-temperature, low-humidity environments.
CH-C1 Office:
Execute “Density Adjustment Process Control” by tapping the following buttons: [User
Tools/Counters] – [Management] – [Auto Color Calibration].
Note:
- This is effective when the development gamma is low (about 0.8 or less) or the OPC electric
potential is high, such as in low-temperature, low-humidity environments.
- After you do this, color calibration is optional.
CE:
Execute SP3-011-002 ([Manual ProCon :Exe] - Density Adjustment).