Technical Bulletin PAGE: 1/2
Subject: Manual correction: the table of SC360/ SC362
From: 2nd Tech Service Sect., MFP/P Tech Service Dept.
Electrical
Transmit/receive
Service manual revision
Retrofit information
Service Manual Correction
① HTML version: Top Page > Main Chapters>Troubleshooting > Service call 300- 398
> SC300 (Engine: Development)
PDF version: page 1062 and 1063 (MP C6502 series Field Service Manual)
Delete the description in bold in the table of SC360 and SC362.
Error Name/ Error Condition/ Major Cause/ Solution
TD sensor adjustment error (K)
TD sensor adjustment error (C)
TD sensor adjustment error (M)
TD sensor adjustment error (Y)
During TD sensor initialization, TD sensor output voltage(Vt) cannot be
adjusted to the target range (target value ±0.2V)
Details:
TD sensor initialization adjust the TD sensor control voltage(Vtcnt) in
order to adjust the TD sensor output voltage(Vt) to target value ±0.2V.
Adjustment flow:
1. Developer presence detection
2. Developer not detected.
OK: Proceeds to Vtcnt adjustment
NG:SC336-0X
3. TD sensor calibration (Fluctuate Vtcnt and measure Vt)
4. TD sensor calibration result judgment
OK: TD sensor calibration succeeded.
NG: SC360-0X
- Loose connection
- Harness broken
- Developer is not new
- Replace the development unit