EasyManuals Logo
Home>Rigol>Test Equipment>DS4024E

Rigol DS4024E User Manual

Rigol DS4024E
329 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #114 background imageLoading...
Page #114 background image
RIGOL Chapter 5 Trigger
5-26 DS4000E User’s Guide
Pattern Trigger
This trigger mode identifies a trigger condition by looking for a specified pattern.
The pattern is a logical ANDcombination of the channels. Each channel can have a
value of high (H), low (L) or dont care (X). A rising or falling edge can be specified
for one channel included in the pattern. When an edge is specified, the oscilloscope
will trigger at the edge specified if the pattern set for the other channels are true
(namely the actual pattern of the channel is the same with the preset pattern). If no
edge is specified, the oscilloscope will trigger on the last edge that makes the pattern
true. If all the channels in the pattern are set to “Dont Care, the oscilloscope will not
trigger.
Press MENU (in the trigger control area (TRIGGER) at the front panel) Type, turn
the multi-function knob to select “Pattern” and press the knob. You can also
press Type continuously to switch to “Pattern” trigger.
At this point, the trigger setting information (include the trigger type, current channel
and trigger level, as shown in the figure below) is displayed at the upper-right side of
the screen and changes with the trigger setting.
Besides, the pattern setting area (as shown in the figure below) is displayed at the
bottom of the screen to display the current pattern setting information (the pattern
of the channel currently selected is displayed in red).
1. Set the channel pattern and adjust the trigger level
1) Select the specified channel
Press Source to select the channel to be included in the desired pattern.
You can select CH1 to CH4 or EXT (please refer to “
Trigger Source”). The
channel currently selected is displayed at the upper-right side of the screen.
At the same time, the pattern of the channel currently selected is
highlighted in red in the pattern setting area at the bottom of the screen.
Note: Channels that are turned off can also be selected as the trigger
source.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS4024E and is the answer not in the manual?

Rigol DS4024E Specifications

General IconGeneral
BrandRigol
ModelDS4024E
CategoryTest Equipment
LanguageEnglish

Related product manuals