EasyManuals Logo

Siemens SINAMICS V20 User Manual

Siemens SINAMICS V20
426 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #352 background imageLoading...
Page #352 background image
Technical specifications
SINAMICS V20 Converter
350 Operating Instructions, 10/2019, A5E34559884-012
Mechanical specifications
Frame size
FSAA
FSAB
FSAC
FSAD
FSA
FSB
FSC
FSD
1)
FSE
with fan
without fan
Outline
dimen-
sions
(mm/in
ch)
W
68/2.7 68/2.7 90.8/3.6 136.6/5.4 90/3.5 90/3.5 140/5.5 184/7.24 240/9.4 245/9.6
H
142/5.6 142/5.6 160.9/6.33 176.5/7.0 166/6.5 150/5.9 160/6.3 182/7.17 206.5/8.1 264.5/10.4
D
107.8/4.2 127.8/5 147/5.8 158.8/6.3 145.5/5.7 145.5 (114.5
2)
)/5.7(4.5
2)
)
164.5/6.5 169/6.7 172.5/6.8 209/8.2
Mounting
methods
Mounting in a control cabinet
Push-through mounting (FSB ... FSE)
1)
Available for three phase AC 400 V converters only.
2)
Depth of Flat Plate converter (400 V 0.75 kW variant only).
Frame size
Net weight (kg)
Gross weight (kg)
unfiltered
filtered
unfiltered
filtered
Three phase AC 400 V converters
FSA
with fan
1.0
1.1
1.4
1.4
without fan
0.9
1.0 (0.9
1)
)
1.3
1.4 (1.3
1)
)
FSB
1.6
1.8
2.1
2.3
FSC
2.4
2.6
3.1
3.3
FSD
7.5 kW
3.7
4.0
4.3
4.6
11 kW
3.7
4.1
4.5
4.8
15 kW
3.9
4.3
4.6
4.9
FSE
18.5 kW
6.2
6.8
6.9
7.5
22 kW
6.4
7.0
7.1
7.7
Single phase AC 230 V converters
FSAA
0.6
0.7
1.0
1.1
FSAB
0.8
0.9
1.2
1.3
FSAC
1.2
1.4
1.3
1.5
FSAD
1.9
2.2
2.1
2.4
FSC
2.5
2.8
3.0
3.2
1)
Weight of Flat Plate converter (400 V 0.75 kW variant only).

Table of Contents

Other manuals for Siemens SINAMICS V20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS V20 and is the answer not in the manual?

Siemens SINAMICS V20 Specifications

General IconGeneral
Power Range0.12 kW to 30 kW
Overload Capacity150% for 60 seconds
Protection ClassIP20
Storage Temperature Range-40°C to +70°C
AltitudeUp to 1000 m without derating
Input Voltage3AC 380 V to 480 V
Output Voltage0 V to Input Voltage
Control ModesV/f control
Ambient Temperature Range-10°C to +60°C
Relative Humidity5% to 95%, non-condensing
Communication InterfacesModbus RTU
Braking ResistorOptional external

Related product manuals