EasyManuals Logo
Home>Tektronix>Test Equipment>MSO58

Tektronix MSO58 Printable Help

Tektronix MSO58
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #260 background imageLoading...
Page #260 background image
Field or control Description
A, B knob controls Use the A knob to select (highlight) the character to change.
Use the B knob to change the value of the character.
Copy Trigger Settings to
Search
Sets the search criteria to match the current oscilloscope trigger settings.
Copy Search Settings to
Trigger
Sets the current oscilloscope trigger settings to match the search criteria.
LIN serial bus search configuration menu
Use the LIN Search configuration menu to define conditions to search for and mark on an LIN bus waveform. You can have
multiple searches on the same bus.
NOTE. Requires option SRAUTO.
Field or control Description
Display Enables or disables displaying search marks on this search.
Stop Acquisition if Event
Found
Stops input acquisition when the search event occurs. Default is not enabled.
Source Select the LIN bus that you want to search.
Mark On Select the type of information for which to search.
Identifier Sets the identifier pattern for which to search.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = Identifier or Identifier & Data.
Data Bytes Sets the number of data bytes for which to search (one to four bytes). Use the A knob to
change the value.
Only available when Mark On = Data or Identifier & Data.
Data Sets the data pattern for which to search. The number of bits shown depends on the Data
Bytes setting.
Tap the Binary or Hex field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = Data or Identifier & Data.
Mark When Sets the mark when condition.
When set to Inside Range or Outside Range, fields are displayed to set a Data Low and Data
High boundary pattern for the specified search range.
Only available when Mark On = Data or Identifier & Data.
A, B knob controls Use the A knob to select (highlight) the digit(s) to change.
Use the B knob to change the value of the digit(s).
Menus and dialog boxes
240 MSO54, MSO56, MSO58, MSO58LP, MSO64 Help

Table of Contents

Other manuals for Tektronix MSO58