EasyManuals Logo
Home>Yealink>Conference System>VCM38

Yealink VCM38 Administrator's Guide

Yealink VCM38
281 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
| Configuring Network Settings | 70
Configuring IPv4
After connected to the wired network, the system can obtain the IPv4 network settings from a Dynamic
Host Configuration Protocol (DHCP) server if your network supports it. You can also configure IPv4
network settings manually.
Before you begin
Make sure that your network mode is set to IPv4 or IPv4&IPv6.
Procedure
1. Do one of the following:
On your web user interface, go to Network > LAN Configuration > IPv4 Config.
On your VCS: go to More > Settings > Network Setting > Wired Network > IPv4.
For VP59, tap > Settings > Network Setting > Wired Network > IPv4.
On your CTP20/CTP18, tap > Settings > Network Setting > Host Network > Network > Wired
Network > IPv4.
2. Configure and save the following settings:
Parameter Description Configuration Method
DHCP
Enable or disable the system to
obtain network settings from the
DHCP server.
Note: the default value is On.
If you change this parameter, the
system will reboot to make the
change take effect.
Web user interface
Endpoint
CTP20/CTP18
Static IP
Enable or disable the system to
use manually configured network
settings.
Default: Off.
If you change this parameter, the
system will reboot to make the
change take effect.
Web user interface
IP Address
Configure the IPv4 address
assigned to the system.
Note: It is configurable only
when the network type is
selected as Static IP. If you
change this parameter, the
system will reboot to make the
change take effect.
Web user interface
Endpoint
CTP20/CTP18

Table of Contents

Other manuals for Yealink VCM38

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink VCM38 and is the answer not in the manual?

Yealink VCM38 Specifications

General IconGeneral
TypeConference microphone
Noise reductionYes
Microphone frequency100 - 16000 Hz
Microphone sensitivity-45 dB
Microphone pick-up range6 m
Number of microphone arrays8
Maximum sound pressure level (1kHz)100 dB
Device interfaceRJ-45
Connectivity technologyWired
Maximum operating distance40 m
Mounting typeCeiling
Product colorSilver
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 90 %
Number of products included1 pc(s)
Harmonized System (HS) code85181000
Power sourceDC/PoE
Sustainability certificatesCE, Federal Communications Commission (FCC), REACH, RoHS
Weight and Dimensions IconWeight and Dimensions
Width127.3 mm
Height66.3 mm

Related product manuals