Page #231 background imageLoading...
Page #231 background image
User's Manual
215
higher or below the specified threshold.
Make sure that the connected camera supports temperature monitoring function.
This function is available on select models.
The thermal detection functions might vary depending on the connected camera. This
section uses heat alarm as an example.
Procedure
Step 1 Select Main Menu > ALARM > Thermal Alarm.
Figure 5-175 Thermal alarm
Step 2 Select a channel and set alarm type to heat alarm, and then enable the function.
Step 3 Select fire mode. The system supports preset mode and zone excluded mode.
Preset mode: Select a preset and then enable the function. The system generates
an alarm once it detects there is a fire.
Zone excluded mode: The system filters the specified high temperature zone.
The system generates an alarm once the rest zone has fire.
Step 4 Configure alarm linkage. For details, see Table 5-43.
Step 5 Click Apply.
5.10.8 Exception
Background Information
When an error in HDD, network, and device occurs, the system performs alarm linkage