EasyManuals Logo
Home>Datalogic>Barcode Reader>QuickScan I QD2400

Datalogic QuickScan I QD2400 User Manual

Datalogic QuickScan I QD2400
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
Enter/Exit Programming Mode
108 QuickScan™ I QD24XX
Code 39 Set Length 1
This feature specifies one of the bar code lengths for Code 39 Length Control. Length 1 is the minimum label
length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s
data characters only. The length can be set from 0 to 50 characters.
Ta bl e 3 provides examples for setting Length 1. See page 217 for detailed instructions on setting this feature.
Table 3. Code 39 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 39 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CC3L1
Select Code 39 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
02 = Length 1 is 2 Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan I QD2400 and is the answer not in the manual?

Datalogic QuickScan I QD2400 Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan I QD2400
CategoryBarcode Reader
LanguageEnglish

Related product manuals