Enter/Exit Programming Mode
68 QuickScan™ I QD24XX
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good read. The good
read LED on time can be set within a range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in
100ms increments. A setting of 00 keeps the LED on until the next trigger pull.
See page 227 in “References” for detailed instructions and examples for setting this feature.
$CLAGL00(CR)
Good Read LED Duration Setting =
Keep LED on until next trigger pull
$CLAGL
Select Good Read LED Duration Setting
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE bar code above, then the bar code at left fol-
lowed by the digits from the Alphanumeric characters in
Appendix D, Keypad representing your desired charac-
ter(s). End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to
abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
003 = Good Read LED
stays on for 300 ms.
Indicators are dimmed during sleep.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan I QD2400 and is the answer not in the manual?

Datalogic QuickScan I QD2400 Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan I QD2400
CategoryBarcode Reader
LanguageEnglish

Related product manuals