Enter/Exit Programming Mode
Product Reference Guide 117
Code 128 Set Length 1
Specifies one of the bar code lengths for Code 128 Length Control. Length 1 is the minimum label length if in
Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data
characters only. The length can be set from 1 to 80 characters.
Tabl e 5 provides some examples for setting Length 1. See page 217 for detailed instructions on setting this feature.
Table 5. Code 128 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Character 07 Characters 15 Characters 80 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 128 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘8’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character