Scanning Features
Product Reference Guide 229
Stand Mode Off Time
This feature specifies the amount of time reader illumination stays off after pulling the trigger when in Stand
Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds).
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield two digits.
F
or example: 2 = 02, 5 = 05, 20 = 20, etc.
3. Go to page 73 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
4. Scan the bar code: Set Stand Mode Illuminator Off Time.
5. Scan the appropriate two digits
fr
om the keypad in Appendix D, Keypad, that represent the setting which
was determined in the steps above. You will hear a two-beep indication after the last
character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit P
rogramming Mode.
This completes the procedure. See Tab le 38 for some examples of how to set this feature.
Table 38. Stand Mode Off Time
STEP ACTION EXAMPLES
1 Desired Setting
500 ms 1 Second 5.5 Seconds 16 Seconds
2 Pad leading zero
01 02 11 32
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT STAND MODE OFF TIME
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘2’ ‘1’ and ‘1’ ‘3’ and ‘2’
6 Scan ENTER/EXIT PROGRAMMING MODE