Example of the clear dampening Command
Dell# clear dampening interface Gi 1/1
Dell#show interfaces dampening Gigabitethernet 1/1
Interface Supp Flaps Penalty Half-Life Reuse Suppress Max-Sup
State
Gi 1/1 Up 0 0 1 2 3 4
Dell#
Link Dampening Support for XML
View the output of the following show commands in XML by adding | display xml to the end of the command.
• show interfaces dampening
• show interfaces dampening summary
• show interfaces interface slot/port
Congure MTU Size on an Interface
In Dell Networking OS, Maximum Transmission Unit (MTU) is dened as the entire Ethernet packet (Ethernet header + FCS + payload).
The link MTU is the frame size of a packet, and the IP MTU size is used for IP fragmentation. If the system determines that the IP packet
must be fragmented as it leaves the interface, Dell Networking OS divides the packet into fragments no bigger than the size set in the ip
mtu command.
NOTE
: Because dierent networking vendors dene MTU dierently, check their documentation when planning MTU sizes
across a network.
The following table lists the range for each transmission media.
Transmission
Media
MTU Range (in bytes)
Ethernet
594-12000 = link MTU
576-9234 = IP MTU
Link Bundle Monitoring
Monitoring linked LAG bundles allows trac distribution amounts in a link to be monitored for unfair distribution at any given time. A
threshold of 60% is dened as an acceptable amount of trac on a member link. Links are monitored in 15-second intervals for three
consecutive instances. Any deviation within that time sends Syslog and an alarm event generates. When the deviation clears, another
Syslog sends and a clear alarm event generates.
The link bundle utilization is calculated as the total bandwidth of all links divided by the total bytes-per-second of all links. If you enable
monitoring, the utilization calculation is performed when the utilization of the link-bundle (not a link within a bundle) exceeds 60%.
To enable and view link bundle monitoring, use the following commands.
• Enable link bundle monitoring.
ecmp-group
• View all LAG link bundles being monitored.
show running-config ecmp-group
• Enable link bundle monitoring on port channel interfaces.
Interfaces
347

Table of Contents

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
BrandDell
ModelS3048-ON
CategorySwitch
LanguageEnglish

Related product manuals