2 Hardware Specifications and Wiring
DVP-PM Application Manual
2-2
Max. input
Terminal Description
Response
time
Current Voltage
PG0+, PG0-, PG1+,
PG1-
Zero point signal input +, - (differential signal input) 200kHz 16mA 5 ~ 24V
DOG0, DOG1
There are two variations according to different
operation modes:
1. DOG signal in zero return mode
2. Start signal for inserting single speed or 2-speed
operation
1ms 6mA 24V
X0~X7 General input points 200kHz 15mA 24V
îš„ DVP20PM00M
Max. input
Terminal Description
Response
time
Current Voltage
START0, START1 For input signals of Start 10ms 6mA 24V
STOP0, STOP1 For input signals of Stop 10ms 6mA 24V
LSP0/LSN0,
LSP1/LSN1
Right limit input/left limit input 10ms 6mA 24V
X1/X2 Right limit input/left limit input (COM) (for Z axis) 10ms 6mA 24V
A0+, A0-, A1+, A1-
MPG A-phase pulse input +, - (differential signal
input) (A1+, A1- are shared by Y and Z )
200kHz 15mA 5 ~ 24V
B0+, B0-, B1+, B1-
MPG B-phase pulse input +, - (differential signal
input) (B1+, B1- are shared by Y and Z)
200kHz 15mA 5 ~ 24V
PG0+, PG0-, PG1+,
PG1-
Zero point signal input +, - (differential signal input) 200kHz 16mA 5 ~ 24V
X3 Zero point signal input (COM) (for Z axis) 100ms 6mA 24V
DOG0, DOG1
There are two variations according to different
operation modes:
1. DOG signal in zero return mode
2. Start signal for inserting single speed or 2-speed
operation
1ms 6mA 24V
X0 Same as DOG0, DOG1 (COM) (for Z axis) 10ms 6mA 24V
X4~X7 General input points 200kHz 15mA 24V
îš„ DVP10PM00M
Max. input
Terminal Description
Response
time
Current Voltage
X0~X7
1. single phase / A-B phase input
2. DOG signal for X-Y-Z-A axis: X0, X2, X4, X6
3. PG signal for X-Y-Z-A axis: X1, X3, X3, X7
200kHz 15mA 24V
X10+, X10-, X11+, X11- MPG+/- pulse input (differential input) 200kHz 15mA 5 ~ 24V
X12+, X12-, X13+, X13- Differential input 200kHz 15mA 5 ~ 24V
Output point specifications:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-PM Series and is the answer not in the manual?

Delta DVP-PM Series Specifications

General IconGeneral
BrandDelta
ModelDVP-PM Series
CategoryController
LanguageEnglish

Related product manuals