3 Functions of Devices in DVP-PM
DVP-PM Application Manual
3-77
3.12.2 Manual Modes
1. There are 8 manual modes in DVP-PM
1. Mechanical zero return 6. 2-speed positioning
2. JOG mode 7. 2-speed positioning interruption
3. Single-speed positioning 8. Variable speed mode
4. Single-speed positioning interruption 9. MPG input
5. Externally triggering single-speed positioning*
Note*: Only DVP-20PM supports this function
2. When several manual modes are enabled at the same time, they will be processed in the following order.
1. STOP 7. Single-speed positioning
2. Mechanical zero return 8. Single-speed positioning interruption
3. JOG+ mode 9. Externally triggering single-speed positioning
4. JOG- mode 10. 2-speed positioning
5. MPG input 11. 2-speed positioning interruption
6. Variable speed mode
When one of the manual modes is being executed and another manual mode is enabled, DVP-PM will
remain the operation of the executing manual mode.
3. There are two types of pulse acceleration/deceleration curves.
1. Trapezoid curve 2. S curve