11 G-code Application
DVP-PM Application Manual
11-3
up in O100 to communicate with PMGDL. Communication format: 115200, 8, N, 1(RTU).
(A) Program for set up COM1
(B)Program for set up COM2
Step 2: Set up PEP settings in PMSoft to enable protection on O100 or other constant programs and
download the program to 20PM00M as below.
(A) Set up PEP settings on programs
(B) Click Download Program
(C) Download settings
(D) Results