14 High Speed Compare and Capture
DVP-PM Application Manual
14-2
3 Y3 Y3
4 Reset C200 Reset C200
5 Reset C204 Reset C204
6 Finish Lead state of CAM Reset C208
7 Engage CAM Reset C212
(2) Setting format of control registers (CRn) for high-speed Capture function
01234567891011
1213
1415Bit
Settings
Output
action
Output terminals
and coun te rs
Capture
function
Data source of
Capture function
Trigger switch of
Capture function
Bit SV 20PM 10PM
0 CP of X axis CP of X axis
1 CP of Y axis CP of Y axis
2 CP of Z axis CP of Z axis
3 C200 count value CP of A axis
4 C204 count value C200 count value
5
-
C204 count value
6
-
C208 count value
Data source for
capture function
[3-0]
7
-
C212 count value
Capture function [5-4] 0 Default:0
0
-
1
-
No action
2,
-
Set
Output action [7-6]
3
-
Reset
0
-
Y0
1
-
Y1
2
-
Y2
3
-
Y3
4
-
Reset C200
5
-
Reset C204
6
-
Reset C208
Output terminal
and counters
[11-8]
7
-
Reset C212
0
X axis PG0 X0
1
X axis MPGB X1
2
X axis MPGA X2
3
X axis LSN X3
4
X axis LSP X4
Trigger switch of
Capture function
[15-12]
5
X axis DOG X5