EasyManuals Logo
Home>Emerson>Transmitter>Micro Motion 1000 Series

Emerson Micro Motion 1000 Series User Manual

Emerson Micro Motion 1000 Series
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
Configuration and Use Manual 69
Optional Configuration
Required Configuration Optional ConfigurationUsing the TransmitterFlowmeter Startup Required Configuration Optional ConfigurationUsing the TransmitterFlowmeter Startup Required Configuration Optional ConfigurationUsing the TransmitterFlowmeter Startup Required Configuration Optional ConfigurationUsing the TransmitterFlowmeter Startup
The preceding terms are related by the following formula:
8.5.2 Special measurement unit procedure
To create a special measurement unit:
1. If necessary, set Volume Flow Type to match the type of special measurement unit you will
create.
2. Identify the simplest base volume or mass and base time units for your special mass flow or
volume flow unit. For example, to create the special volume flow unit pints per minute, the
simplest base units are gallons per minute:
• Base volume unit: gallon
• Base time unit: minute
3. Calculate the conversion factor using the formula below:
Note: 1 gallon per minute = 8 pints per minute
4. Name the new special mass flow or volume flow measurement unit and its corresponding
totalizer measurement unit:
• Special volume flow measurement unit name: Pint/min
• Volume totalizer measurement unit name: Pints
Note: Special measurement unit names can be up to 8 characters long (i.e., 8 numbers or letters), but
only the first 5 characters appear on the display.
5. To apply the special measurement unit to mass flow or volume flow measurement, select
Special from the list of measurement units (see Section 6.4.1 or 6.4.2).
ConversionFactor
x BaseUnit(s)[]
y SpecialUnit(s)[]
---------------------------------------------=
x BaseUnit(s)[]y SpecialUnit(s)[]=
1 (gallon per minute)
8 (pints per minute)
------------------------------------------------------- 0.125 (conversion factor)=

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Micro Motion 1000 Series and is the answer not in the manual?

Emerson Micro Motion 1000 Series Specifications

General IconGeneral
BrandEmerson
ModelMicro Motion 1000 Series
CategoryTransmitter
LanguageEnglish

Related product manuals