The operational parameters are defined in the Hypermotion mode of the Remote Panel, in
the LCD secondary menu.
Operational Parameter Value Range Default Value
# Blocks 1 to 4 1
Pre-Roll from 00s00fr to 5s00fr 00s00fr
PGMSpeed 50, 100, 200, 400, 800, 1600% 100
2nd Lever +/- 1600%, 0-1600% +/- 1000
Specific Behavior of Remote Panel Keys
• RECORD: Pressing this key when no block is in RECORD and no block is selected
starts recording on the first block. Previously recorded material remains unchanged.
• RECORD: Pressing this key while the current block is recording clears all memory
blocks in play or recorded state. The material on the current recording block is not
deleted. It is moved to the first block, and the camera starts recording on the next
empty block (block 2).
• RECORD: The Remote beeps if the CAM key refers to an empty block.
• TAKE: This key is operational in REC STANDBY mode. When the user presses the
TAKE key, if a block was in play mode, it remains in this mode. If no block was in play
mode, the previous recording block starts playing.
• CLEAR (+CAM key): Pressing the CLEAR key deletes the data on the memory
block that is in PLAY (or on the selected block) and shifts the recording block to the
left.
Cue Points Management
Note
The cue points are only operational when all memory blocks have been recorded
once.
• When a new ARM/REC command is issued on a block, all its cue points are cleared.
• If the Last Cue command cannot access the desired TC preroll, the player remains on
the current cue point.
• If the Last Cue command refers to a TC that does not exist anymore, the key beeps
but the OSD still displays the number of the cue that you wanted to go to.
216 9. Advanced Control Modes
EVS Broadcast Equipment SA Issue 12.05.A- May 2014