EasyManuals Logo
Home>Gehl>Compact Loader>RT210

Gehl RT210 User Manual

Gehl RT210
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #181 background imageLoading...
Page #181 background image
Troubleshooting
Printed in U.S.A. 171 50940411/G0219
Electrical Troubleshooting
Table 52: Electrical Troubleshooting
Problem Possible Cause Corrective Action
Loss of electrical power
Battery terminals or cables loose or
corroded
Clean battery terminals/cable
connections and tighten
Battery malfunction
Test battery. Recharge/replace as
necessary
Blown main fuse
Correct over-current problem and replace
main fuse. See “Fuses and Relays” on
page 152
Instrument display does not activate when
ignition is on
Blown main fuse
Correct over-current problem and replace
main fuse. See “Fuses and Relays” on
page 152
Battery terminals or cables loose or
corroded
Clean battery terminals/cable
connections and tighten
Ignition switch malfunction Replace switch
In very cold weather, display screen slow
to display
Wait a few minutes for display to activate
Starter does not engage when key switch
turned to start position
Loose/corroded starter electrical
connections
Check/tighten/clean connections
Battery terminals or cables loose or
corroded
Clean battery terminals/cable
connections and tighten
Starter relay malfunction Contact dealer
Battery malfunction
Test battery. Recharge/replace as
necessary
Starter solenoid malfunction Contact dealer
Starter or pinion malfunctioning Repair/replace as needed
Error code “0”. Arm rest/safety bar in
raised position; cab door not closed (if
equipped)’ operator’s seat not occupied
Lower arm rests/safety bars to operating
position. Engine will not start with either
arm rest/safety bar raised, or the cab
door open (if equipped). Occupy
operator’s seat
Work/road lights malfunction
Single light not working; light bulb burned
out, faulty wiring
Check and replace light bulb as needed,
check wiring connections
No lights; blown fuse
Correct over-current problem and replace
fuse. See “Fuses and Relays” on
page 152
Light switch malfunction Replace light switch
Poor electrical ground Check ground wire connections