Controls
Printed in U.S.A. 49 50940411/G0219
Switches/Indicators
Table 23: Switches/Indicators
No Item Description
A Power-A-Tach®
Located on left panel. Press and hold bottom of switch to lock attachment
onto the Power-A-Tach® quick attach system hitch; press and hold top of
switch to unlock the attachment.
See “Connecting/Disconnecting Attachments” on page 104.
B Parking Brake
Press top of switch to apply parking brake. Press and hold top of switch to
release parking brake.
Indicator in switch is lit when parking brake is applied.
IMPORTANT: Parking brake is applied when either, or both, safety bar/
arm rests are in the raised position, operator is not in seat and door (if
equipped) is opened.
C Heat/Air Conditioning Fan (HVAC)
Located on left panel. See “Cab Heat and Air Conditioning (Option)” on
page 61.
D Front Windshield Wiper/Washer (option)
Press bottom of switch to activate front windshield wiper; press and release
top of switch to deactivate.
Press and hold top of switch to operate front windshield washer spray.
Indicator in switch is lit when front windshield wiper is activated.
E Rear Windshield Wiper/Washer
Press bottom of switch to activate rear windshield wiper; press and release
top of switch to deactivate.
Press and hold top of switch to operate rear windshield washer spray.
Indicator in switch is lit when rear windshield wiper is activated.
F Auxiliary High-Flow Hydraulics See “Auxiliary Hydraulics Operation” on page 107.
G Self-Leveling Cancel (option)
Press top of switch to deactivate self-leveling; press bottom of switch to
restore the self-leveling function.
Indicator in switch is lit when self-leveling is deactivated.
H Work Lights
Move switch to the middle position to activate the front work lights; press the
top of switch to activate both the front and rear work lights; press bottom of
switch to deactivate work lights. See “Work Lights” on page 67.
Indicator in switch is lit when work lights are on.
I Air Conditioning Compressor (HVAC)
Located on left panel. See “Cab Heat and Air Conditioning (Option)” on
page 61.
A
Fig. 7 – Switches/Indicators
B
C
E
F
G
D
IH

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gehl RT210 and is the answer not in the manual?

Gehl RT210 Specifications

General IconGeneral
BrandGehl
ModelRT210
CategoryCompact Loader
LanguageEnglish

Related product manuals