COMMISSIONING
138 Service Manual Part No.: 4417340 Revision 1
954 SmartServo FlexLine
7.3.8.3 Some Important Features
ď‚§ Temperature calculations can be:
o Standard (just simple averaging the spot temperatures).
o Enhanced (averaging the spot temperatures and taking into
account the contribution of each spot in respect to its
immersion).
o Custom (as standard but then giving it a weighing factor).
o A temperature-range check can be turned on. In this
case, if spot elements are out of range, a fail state results
(if not skipped), see Figure 7-23.
Figure 7-23
Temperature range check feature
• A median filter can be turn on or off, which eliminates spikes
of each individual calculated spot temperature.
• An averaging constant filter can be turned on or off, which
takes a certain part of the previous calculated average
temperature and a certain part of the new calculated
temperature into account.
• Low element usage with following possible sub-settings can
be applied:
″ No exclusion
″ Static exclusion
″ Dynamic exclusion
These settings are then to be refined further with:
″ Exclude zone
″ Smoothing level
″ Low element behaviour

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell FlexLine SmartServo 954 and is the answer not in the manual?

Honeywell FlexLine SmartServo 954 Specifications

General IconGeneral
BrandHoneywell
ModelFlexLine SmartServo 954
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals