COMMISSIONING
150 Service Manual Part No.: 4417340 Revision 1
954 SmartServo FlexLine
All the HART universal commands and some common practice
commands are supported by HCI-HAO. These are listed in the below
tables.
HART Universal Ccommands
Command no. Description
0 Read Unique Identifie
1 Read P
ima
yVa
iable
2 Read Loop Current and Percen
age of Range
3 Read Dynamic variables and Loop Cur
ent
4 Reserved
5 Reserved
6 Write Polling Address
7 Read Loop Configu
ation
8 Read Dynamic Variable Classifications
9 Read Device Variable With Status
10 Reserved
11 Read Unique Identifie
Associated
ith Tag
12 Read Message
13 Read Tag, Descripto
,Date
14 Read PV Senso
Information
15 Read Device Information
16 Read Final Assembly Numbe
17 Write Message
18 Write Tag, Descripto
,Date
19 Write Final Assembly Numbe
20 Read Long Tag
21 Read Unique Identifie
Associated With Long Tag
22 W
ite Long Tag
HART Common Practice Commands
Command no. Description
34 Write Primary Variable Damping Value
35 Write Primary Variable Range Values
36 Set Prima
y Variable Upper Range Value
37 Set Prima
y Variable Lower Range Value
38 Reset Configuration Changed Flags
40 Enter / Exit Fixed Cu
rent Mode
41 Perform Self Test
42 Perform Device Reset
44 Write Primary Variable Uni
s
48 Read Additional Device S
atus
53 Write Device Variable Uni
s
72 Squawk