COMMISSIONING
Part No.: 4417340 Revision 1 Service Manual 145
954 SmartServo FlexLine
Name
Explanation
Value Range Default
[Element skipping]
Enables or disables the fact that
elements can be skipped if an
element is outside a temperature
range.
<enable>
<disable>
<disable>
[Maximum skipped elements]
The number of elements that
can be skipped
<1,2> <1>
[Median filter]
Enables or disables a
median filter of 5 levels deep
(spike filtering).
<enable>
<disable>
<enable>
[Temperature calculation method]
The way the average
temperature is calculated (see
also features above)
<Standard>
<Custom>
<Enhanced>
<Enhanced>
[MRT length table]
[Only for MRT]
Specifies whether a fixed range
of MRT resistors is used (= <F> )
or user configured lenghts (=
<T>). Fixed lengths are:
0.65, 1.25, 1.95, 2.85, 4.15, 5.65
1 character
<F>
<T>
<F>
[MRT element length
used if MRT length table is 'T']
[Only for MRT]
The lengths of the MRTs
including anchor eye
floating point numbers:
<-x.x .. +x.x>
<0.0>
Engauge * Vapour temperature * Tab
NOTE: Some settings for Vapour temperature calculations are
shared via the product temperature settings.
☛ The following entities can be set by Engauge or HART
SmartView for a specific functioning of the FII-RTD module in an
instrument. The default values are available after initialization of the non
volatile memory; so check each entity for its correctness.