Using iLO 131
āˆ’ SSH allowing two simultaneous connections. IP address or DNS name,
login name and password are required to start a CLI session using SSH.
āˆ’ Telnet protocol using three simultaneous connections
All six connections can be active simultaneously. After serial CLI is enabled on
the Global Settings screen, the iLO CLI is invoked by entering ESC (. The SSH
and telnet sessions start the CLI after authentication.
CLI Commands
The following commands are supported in this release of CLI. The same
command set is supported through the serial port, the SSH connection, and telnet
connection
The privilege level of the logged in user is checked against the privilege required
for the command. The command is only executed if the privilege levels match. If
the serial and Virtual Serial Port CLI session status is set to Enabled-No
Authentication, then all the commands except Remcons are executed without
checking the privilege level. The Remote Console Virtual Serial Port session
displays the login prompt.
The supported commands are:
•
•
Escape
āˆ’ ESC ( invokes the serial CLI connection. This is not necessary for SSH
or telnet sessions because they automatically start a CLI session after a
successful login.
āˆ’ ESC Q stops the CLI session and terminates the SSH and telent
connection.
āˆ’ ESC R ESC r ESC R resets the system.
āˆ’ ESC ^ powers on the system.
āˆ’ ESC ESC erases the current line.
There is a 1–second timeout for entering any of the escape sequence
characters.
Help

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrated Lights-Out and is the answer not in the manual?

HP Integrated Lights-Out Specifications

General IconGeneral
BrandHP
ModelIntegrated Lights-Out
CategorySoftware
LanguageEnglish

Related product manuals