SWEep Subsystem
Copyright © ITECH Electronic Co., Ltd. 96
Chapter14 SWEep Subsystem
SWEep:VOLTage:STARt <NRf+>[,<NRf+>,<NRf+>]
This command is used to set and query the start voltage of Sweep.
<NRf+>: initial voltage setting value, or initial voltage MINimum or MAXimum or
DEFault setting
Note:
In single-phase (including AC, ACDC, DC, DCAC), there is only one parameter; in
three-phase, three parameters must be taken.
Syntax
SWEep:VOLTage:STARt <NRf+>[,<NRf+>,<NRf+>]
Argument
<NRf+>[,<NRf+>,<NRf+>]
*RST
0
Query syntax
SWEep:VOLTage:STARt? [A|B|C][MAXimum|MINimum|DEFault]
Returns
<NR2>
Example
SWEep:VOLTage:STARt 100 //Set the starting voltage of sweep to 100V.
SWEep:VOLTage:STARt? //Query the setting value of sweep starting
voltage.
SWEep:VOLTage:STARt? MAX //Query the maximum value of sweep initial
Voltage.
SWEep:VOLTage:STOP <NRf+>[,<NRf+>,<NRf+>]
This command is used to set and query the stop voltage of sweep.
<NRf+>: stop voltage setting value, or stop voltage MINimum or MAXimum or
DEFault setting.
Note:
In single-phase (including AC, ACDC, DC, DCAC), there is only one parameter; in
three-phase, three parameters must be taken.
Syntax
SWEep:VOLTage:STOP <NRf+>[,<NRf+>,<NRf+>]

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals