Output Commands
Copyright © ITECH Electronic Co., Ltd. 49
Example
OUTP:PROT:WDOG ON
OUTPut:PROTection:WDOG:DELay <NRf+>
This command sets and queries the time of the communication watchdog, unit: s.
Syntax:
OUTPut:PROTection:WDOG:DELay <NRf+>
Arguments:
MINimum|MAXimum|DEFault
Query syntax:
OUTPut:PROTection:WDOG:DELay?
Returns:
MINimum|MAXimum|DEFault
Example
OUTPut:PROTection:WDOG:DELay 100
OUTPut:IMPedance[:STATe] <CPD>[,A|B|C|CH1|CH2|CH3]
This command is used to set and query the output state of the impedance.
0|OFF indicates that the function is turned off.
1|ON indicates that the function is turned on.
A|B|C|CH1|CH2|CH3 means to specify a phase or a channel in three-phase mode
or multi-channel mode.
Syntax:
OUTPut:IMPedance[:STATe] <CPD>[,A|B|C|CH1|CH2|CH3]
Arguments:
0|OFF|1|ON
Query syntax:
OUTPut:IMPedance[:STATe]? [A|B|C|CH1|CH2|CH3]
Returns:
0|OFF|1|ON
Example
OUTP:IMP ON //Turn on the output impedance.
OUTP:IMP OFF,A //Turn off the output impedance function of phase A.

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals