SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 33
[SOURce:]CURRent:LIMit:HIGH <NRf+> [,CH1|CH2|CH3]
This command sets and queries the upper limit of RMS current.
Note: the second parameter is optional and only valid in multi-channel mode.
Syntax:
CURRent:LIMit:HIGH <NRf+> [,CH1|CH2|CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
CURRent:LIMit:HIGH? [CH1|CH2|CH3],[MAXimum|MINimum|DEFault]
Returns:
MAXimum|MINimum|DEFault
Example:
CURR:LIMit:HIGH 5 //Set the power supply current limit value to 5A.
CURR:LIMit:HIGH 5 ,CH1 //In multi-channel mode, set the current limit value
of channel 1 to 5A.
[SOURce:]CURRent:LIMit:LOW <NRf+> [,CH1|CH2|CH3]
This command sets and queries the lower limit of RMS current.
Note: the second parameter is optional and only valid in multi-channel mode.
Syntax:
CURRent:LIMit:LOW <NRf+> [,CH1|CH2|CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
CURRent:LIMit:LOW? [CH1|CH2|CH3],[MAXimum|MINimum|DEFault]
Returns:
MAXimum|MINimum|DEFault
Example:
CURR:LIMit:LOW 1 //Set the current lower limit to 1A
CURR:LIMit:LOW 1 ,1 //Under multi-channel mode, set the current lower
limit to 1A

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals