EasyManuals Logo
Home>ITech>Power Supply>IT7900 Series

ITech IT7900 Series Programming Guide

ITech IT7900 Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #149 background imageLoading...
Page #149 background image
ISLand Subsystem
Copyright © ITECH Electronic Co., Ltd. 137
Syntax
ISLand:CURRent:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]
Arguments
<NRf+>
Query syntax
ISLand:CURRent:CONTrol:LEVel? [A|B|C|CH1|CH2|CH3]
Returns
MINimum|MAXimum|DEFault
Example
ISLand:CURRent:CONTrol:LEVel 1
ISLand:CURRent:CONTrol:LEVel?
ISLand:POWer:CONTrol[:STATe] <CPD>[,CH1|CH2|CH3]
This command is used to set the function of detecting the input power status
during island simulation.
Syntax
ISLand:POWer:CONTrol[:STATe] <CPD>[,CH1|CH2|CH3]
Arguments
0|OFF|1|ON
Query syntax
ISLand:POWer:CONTrol[:STATe]? [CH1|CH2|CH3]
Returns
0|1
Example
ISLand:POWer:CONTrol 0,CH2
ISLand:CURRent:CONTrol?
ISLand:POWer:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]
This command is usedt to set the power threshold to detect the input power
during island simulation.
Syntax
ISLand:POWer:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals