EasyManuals Logo
Home>ITech>Power Supply>IT7900 Series

ITech IT7900 Series Programming Guide

ITech IT7900 Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
SENSe Commands
Copyright © ITECH Electronic Co., Ltd. 55
SENSe:FILTer:LEVel <CPD>
This command is used to set and query the filter level of the meter.
Syntax:
SENSe:FILTer:LEVel <CPD>
Arguments:
SLOW|MEDIUM|FAST
Query syntax:
SENSe:FILTer:LEVel?
Returns:
SLOW|MEDIUM|FAST
Example
SENS:FILT:LEV FAST
SENSe:LOOP:SPEed <CPD>
This command is used to set and query the loop speed.
Syntax:
SENSe:LOOP:SPEed <speed>
Arguments:
HIGH|LOW
Default value:
HIGH
Query syntax:
SENSe:LOOP:SPEed?
Returns:
HIGH|LOW
Example
SENS:LOOP:SPE LOW
SENSe:EXTernal:FREQuency <CPD> [CH1, CH2, CH3]
This command is used to set and query the external frequency lock function.
the second parameter is optional and only valid in multi-channel mode.

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals