SENSe Commands
Copyright © ITECH Electronic Co., Ltd. 55
SENSe:FILTer:LEVel <CPD>
This command is used to set and query the filter level of the meter.
Syntax:
SENSe:FILTer:LEVel <CPD>
Arguments:
SLOW|MEDIUM|FAST
Query syntax:
SENSe:FILTer:LEVel?
Returns:
SLOW|MEDIUM|FAST
Example
SENS:FILT:LEV FAST
SENSe:LOOP:SPEed <CPD>
This command is used to set and query the loop speed.
Syntax:
SENSe:LOOP:SPEed <speed>
Arguments:
HIGH|LOW
Default value:
HIGH
Query syntax:
SENSe:LOOP:SPEed?
Returns:
HIGH|LOW
Example
SENS:LOOP:SPE LOW
SENSe:EXTernal:FREQuency <CPD> [CH1, CH2, CH3]
This command is used to set and query the external frequency lock function.
the second parameter is optional and only valid in multi-channel mode.