SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 37
Example:
PVOLtage B,300.0
PVOLtage B,MAX
PVOLT? B
PVOLT? B,MAX
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]:D
C <NRf+>,[NRf+],[NRf+]
DC voltage setting command in normal mode.
<NRf+>: DC voltage setting value.
Syntax:
VOLTage[:LEVel][:IMMediate][:AMPLitude]:DC <NRf+>,[NRf+],[NRf+]
Query syntax:
VOLTage[:LEVel][:IMMediate][:AMPLitude]:DC?
*RST:
0V
Example
VOLTage:DC 300.0
VOLTage:DC?
VOLT:DC? MIN
[SOURce:]PVOLtage[:LEVel][:IMMediate][:AMPLitude]:D
C <phase>,<NRf+>
In normal mode, set and query the DC voltage value of a phase.
phase: phase identification.
NRf+: DC voltage setting value.
Syntax:
PVOLtage [:LEVel][:IMMediate][:AMPLitude]:DC <phase>,<NRf+>
Query syntax:
PVOLtage[:LEVel][:IMMediate][:AMPLitude]:DC? <phase>, [MAXimum|
MINimum|DEFault]
Example
PVOLTage:DC C,30.0
PVOLTage:DC? B
PVOLT:DC? B,MIN