SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 44
[SOURce:]WAVE[:IMMediate] <wave>,[wave],[wave]
This command is used to set and query the waveform in Normal mode.
<wave>: waveform index value.
âš« Sine
âš« Square
âš« Saw
âš« Triangle
âš« Trapezoid
âš« Clipped-sine
Syntax:
WAVE[:IMMediate] <wave>,[wave],[wave]
Query syntax:
WAVE?
Example
WAVE SIN //Set the waveform to Sine in the present mode.
WAVE? //Query the waveform in present mode.
[SOURce:]PWAVe[:IMMediate] <phase>,<wave>
This command is used to set and query the waveform of specified phase in
Normal mode.
<phase>: phase index value.
<wave>: waveform index value.
âš« Sine
âš« Square
âš« Saw
âš« Triangle
âš« Trapezoid
âš« Clipped-sine
Syntax:
PWAVe[:IMMediate] <phase>,<wave>
Query syntax:
PWAVe? <phase>]
*RST:
0-Sine
Example
PWAV C,"Sine" //Set the waveform of phase C to Sine.