SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 47
Arguments:
FUNDamental|TOTal
Query syntax:
CONFigure:HARMonic:THD:FORMula?
Example
CONF:HARM:THD:FORM TOTal //Set the harmonic measurement formula to
r%
[SOURce:]CONFigure:HARMonic:TABLe:TYPE <CPD>
This command is used to set and query the display type of the harmonic distortion
table.
Syntax:
CONFigure:HARMonic:TABLe:TYPE <CPD>
Arguments:
<ALL|EVEN|ODD>
Query syntax:
CONFigure:HARMonic:TABLe:TYPE?
Example
CONF:HARM:TABL:TYPE ODD
[SOURce:]CONFigure:HARMonic:TABLe:SELect <CPD>
This command is used to set and query the data type of the harmonic distortion
list, whether it is voltage harmonic or current harmonic.
Syntax:
CONFigure:HARMonic:TABLe:SELect <CPD>
Arguments:
<U|I>
Query syntax:
CONFigure:HARMonic:TABLe:SELect?
Example
CONF:HARM:TABL:SEL U //Select to display voltage harmonic data.