SENSe Commands
Copyright © ITECH Electronic Co., Ltd. 57
frequency of the machine is within the current set frequency range, the external
frequency will be used, otherwise the frequency set by the user will be used for
output.
Syntax:
SENSe:EXTernal:FREQuency:OFFSet:LOW <NRf>,[CH1, CH2, CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
SENSe:EXTernal:FREQuency:OFFSet:LOW? [CH1, CH2, CH3]
Returns:
<NRf>
Example:
SENS:EXT:FREQ:OFFS:LOW 50
SENSe:EXTernal:FREQuency:PHASe <NRf>,[CH1, CH2,
CH3]
This command is used to set and query the angular difference between the
machine and the external frequency.
Meaning: when the external frequency lock function is turned on, the output
phase of the machine maintains a fixed angular difference with the external
frequency.
Syntax:
SENSe:EXTernal:FREQuency:PHASe <NRf>,[CH1, CH2, CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
SENSe:EXTernal:FREQuency:PHASe? [CH1, CH2, CH3]
Returns:
<NRf>
Example:
SENS:EXT:FREQ:PHAS 1

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals