SENSe Commands
Copyright © ITECH Electronic Co., Ltd. 57
frequency of the machine is within the current set frequency range, the external
frequency will be used, otherwise the frequency set by the user will be used for
output.
Syntax:
SENSe:EXTernal:FREQuency:OFFSet:LOW <NRf>,[CH1, CH2, CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
SENSe:EXTernal:FREQuency:OFFSet:LOW? [CH1, CH2, CH3]
Returns:
<NRf>
Example:
SENS:EXT:FREQ:OFFS:LOW 50
SENSe:EXTernal:FREQuency:PHASe <NRf>,[CH1, CH2,
CH3]
This command is used to set and query the angular difference between the
machine and the external frequency.
Meaning: when the external frequency lock function is turned on, the output
phase of the machine maintains a fixed angular difference with the external
frequency.
Syntax:
SENSe:EXTernal:FREQuency:PHASe <NRf>,[CH1, CH2, CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
SENSe:EXTernal:FREQuency:PHASe? [CH1, CH2, CH3]
Returns:
<NRf>
Example:
SENS:EXT:FREQ:PHAS 1