WAVEform Subsystem
Copyright © ITECH Electronic Co., Ltd. 124
ame">
*RST
Sine
Query syntax
PWAVeform? <phase/chan>
Returns
<string>
Example
PWAVE CH1,"Sine" // Set the channel 1 waveform of the current mode to Sine.
PWAVE A,"Sine" // Set the phase A waveform of the current mode to Sine.
PWAVE? A // Query the waveform of phase A.
PWAVE? CH1 // Query the waveform of channel 1.
WAVEform:EDIT:PARameter <phase/chan>,<percent1>
This command is used to set and query the waveform parameters of a
phase/channel (for example, the percentage of clipping wave. For waveform
types without parameters, this parameter is invalid).
Syntax
WAVEform:EDIT:PARameter <phase/chan>,<percent1>
Arguments
<A|B|C|CH1|CH2|CH3>,<0-0.5>|<0-0.25>
Query syntax
WAVEform:EDIT:PARameter? <phase/chan>
Returns
<NRF>
Example
WAVE:EDIT:PAR 0.25,0.25,0.25
WAVE:EDIT:PAR? // Query waveform parameters of all phases/channels.
WAVE:EDIT:PAR? A //Query the waveform parameters of phase A.
WAVE:EDIT:PAR? CH1 // Query the waveform parameters of channel 1.
WAVEform:EDIT:THD:CLEar
This command is used to clear the edited memory data of the THD wave.