STATus Commands
Copyright © ITECH Electronic Co., Ltd. 119
Arguments
0-0x7fffffff
Default value
0
Example
STAT:QUES:NTR 128
Query syntax
STATus:QUEStionable:NTRansition?
Returns
<NR1> This is a decimal value with a binary weighted sum.
STATus:QUEStionable:PTRansition
Sets the value of the PTR (Positive-Transition) registers. These registers
serve as a polarity filter between the Questionable Condition and
Questionable Event registers. When a bit in the PTR register is set to 1,
then a 0-to-1 transition of the corresponding bit in the Questionable
Condition register causes that bit in the Questionable Event register to be
set. STATus:PRESet sets all bits in the PTR registers and clears all bits in
the NTR registers.
Syntax
STATus:QUEStionable:PTRansition <NR1>
Arguments
0-0x7fffffff
Default value
0
Example
STAT:QUES:PTR 128
Query syntax
STATus:QUEStionable:PTRansition?
Returns
<NR1> This is a decimal value with a binary weighted sum.
STATus:OPERation[:EVENt]?
This command can read the parameter from operation event register. After
executing this order, operation event register is reset.

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals