Output Commands
Copyright © ITECH Electronic Co., Ltd. 52
Syntax:
OUTPut:ON:PHASe:LEVel <NRf+>
Arguments:
MINimum|MAXimum|DEFault
Query syntax:
OUTPut:ON:PHASe:LEVel?
Returns:
MINimum|MAXimum|DEFault
Example
OUTP:ON:PHAS:LEV 30
OUTPut:OFF:PHASe:MODE <CPD>
This command is used to set and query the phase control mode when the power
output is turned off:
PHASe: when the power output is OFF, the output will be turned off at the set
phase angle
IMMediate: when the power output is OFF, the output is turned off at 0 phase
angle
Syntax:
OUTPut:OFF:PHASe:MODE <CPD>
Arguments:
PHASe|IMMediate
Query syntax:
OUTPut:OFF:PHASe:MODE?
Returns:
PHASe|IMMediate
Example
OUTP:OFF:PHAS:MODE PHAS
OUTPut:OFF:PHASe:LEVel <NRf+>
This command is used to set and query the phase angle when the power output is
turned off.
Syntax:
OUTPut:OFF:PHASe:LEVel <NRf+>