EasyManuals Logo
Home>ITech>Power Supply>IT7900 Series

ITech IT7900 Series Programming Guide

ITech IT7900 Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
SENSe Commands
Copyright © ITECH Electronic Co., Ltd. 56
Syntax:
SENSe:EXTernal:FREQuency <CPD> [CH1, CH2, CH3]
Arguments:
OFF|FREQency|PHASe
Query syntax:
SENSe:EXTernal:FREQuency?
Returns:
OFF|FREQency|PHASe
Example:
SENS:EXT:FREQ OFF
SENSe:EXTernal:FREQuency:OFFSet:HIGH <NRf>,[CH1,
CH2, CH3]
Set and query the frequency upper limit value of the external frequency lock
function. the second parameter is optional and only valid in multi-channel mode.
Meaning: when the external frequency lock function is turned on, and the external
frequency of the machine is within the current set frequency range, the external
frequency will be used, otherwise the frequency set by the user will be used for
output.
Syntax:
SENSe:EXTernal:FREQuency:OFFSet:HIGH <NRf>,[CH1, CH2, CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
SENSe:EXTernal:FREQuency:OFFSet:HIGH? [CH1, CH2, CH3]
Returns:
<NRf>
Example:
SENS:EXT:FREQ:OFFS:HIGH 100
SENSe:EXTernal:FREQuency:OFFSet:LOW <NRf>,[CH1,
CH2, CH3]
Set and query the frequency lower limit value of the external frequency lock
function. the second parameter is optional and only valid in multi-channel mode.
Meaning: when the external frequency lock function is turned on, and the external

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals